A weekly walk-through catches hazards that drift in between daily checks: blocked exits, expired permits, missing guardrails, deteriorating equipment. OSHA doesn't leave site inspection to chance — 29 CFR 1926.20(b)(2) requires the employer's accident-prevention program to provide for frequent and regular inspections of the job site, materials, and equipment, made by a competent person. A documented weekly inspection is how that duty is met and evidenced, and it demonstrates a proactive safety program if an incident is later investigated.

When the walk-through turns up unsafe equipment, 1926.20(b)(3) requires it to be removed from service — tagged out, locked out, or taken off the site — until it is brought into compliance. The competent person doing the inspection is someone who can identify hazards and has the authority to correct them (defined at 1926.32(f)).

This is a broad, cross-cutting checklist: each line touches a different OSHA subpart (egress, fire, electrical, HazCom, housekeeping). Any FAIL is logged with a corrective action and a target date.

How to use this checklist#

Fill in the date, inspector, location, and area covered. Walk the site and mark each item Pass, Fail, or N/A, recording specifics in the notes column. Because the checklist spans the whole site, use N/A freely for conditions that don't apply to the area inspected. Open corrective actions carry a target date and are closed out on a later walk-through. The record is signed by the competent person and the supervisor.

Weekly site safety inspection items#

#Inspection itemPassFailN/ANotes
1Site signage is in place: hazard signs, PPE-required signs, emergency contact numbers.
2Emergency exits and evacuation routes are unobstructed and clearly marked.
3Muster points are posted, accessible, and staff know their assigned location.
4First-aid kits are stocked, sealed where required, and within expiration dates.
5Eyewash stations and emergency showers are accessible, tagged, and operational.
6Fire extinguishers are mounted, charged, and have current monthly inspection tags.
7Fire alarm pull stations and detectors are unobstructed and tested per schedule.
8Walkways and stairs are clear of trip hazards, debris, cords, hoses, and standing water.
9Stair handrails and guardrails are intact and securely fastened.
10Floor openings are covered, marked, and rated for the load they may carry.
11Lighting is adequate in all work, storage, and circulation areas.
12Electrical panels have 36 inches of clearance and are labeled with circuit IDs.
13Extension cords are in good condition, not chained together, and not in walkways.
14GFCI protection is in place on outdoor and wet-area outlets; tested monthly.
15Compressed gas cylinders are stored upright, secured, and capped when not in use.
16Flammable liquids are in approved cabinets or safety cans; quantities within limits.
17Chemical containers are labeled (HazCom/GHS); SDS sheets accessible to workers.
18Waste, scrap, and combustible debris are collected and removed regularly.
19Tools and equipment are stored properly; damaged items tagged out and removed.
20Posted permits (hot work, confined space, energized work) are current and signed.
21Lockout/tagout devices, locks, and tags are available at maintenance points.
22Material storage is stable, on level ground, and not blocking access or egress.
23All required PPE is available at the entry/distribution point and stocked.
24Site security: gates, fencing, and barriers are intact; unauthorized access prevented.
25Inspection log is up to date and any open corrective actions have target dates.

Corrective actions taken#

Describe any issues found and the steps taken to correct them. Unsafe equipment is tagged or locked out under 1926.20(b)(3); open items carry a named owner and a target date and are verified closed on a later walk-through.

Inspection sign-off#

  • Inspector signature: __________________________
  • Supervisor signature: __________________________
  • Inspection result: ☐ All items passed ☐ Issues require follow-up

Disclaimer#